Home » Products » Gas analyzers for flue gases » Flue gas analyzers for industry and power generation » testo 350 Analyzer box
Order number: 0632 3510
testo 350 analyzer unit, equipped with O2, including differential pressure sensor, temperature probe input type K NiCr-Ni and type S, Pt10Rh-Pt, Testo data bus connection, rechargeable battery, integrated combustion air probe (NTC), trigger input, measure
Video
Files
Temperature – NTC
|
Ambient temperature probe
|
---|---|
Measuring range
|
-20 to +50 °C
|
Accuracy
|
±0.2 °C (-10 to +50 °C)
|
Resolution
|
0.1 °C (-20 to +50 °C)
|
Temperature – TC Type K (NiCr-Ni)
|
|
---|---|
Measuring range
|
-200 to +1370 °C
|
Accuracy
|
±0.4 °C (-100 to +200 °C)
±1 °C (-200 to -100.1 °C) ±1 °C (200.1 to +1370 °C) |
Resolution
|
0.1 °C (-200 to +1370 °C)
|
Temperature – TC Type S (Pt10Rh-Pt)
|
|
---|---|
Measuring range
|
0 to +1760 °C
|
Accuracy
|
±1 °C (0 to +1760 °C)
|
Resolution
|
0.1 °C (0 to +1760 °C)
|
Differential Pressure – Piezoresistive
|
|
---|---|
Measuring range
|
-40 to +40 hPa
-200 to +200 hPa |
Accuracy
|
±1.5 % of mv (-40 to -3 hPa)
±1.5 % of mv (+3 to +40 hPa) ±0.03 hPa (-2.99 to +2.99 hPa) ±1.5 % of mv (-200 to -50 hPa) ±1.5 % of mv (+50 to +200 hPa) ±0.5 hPa (-49.9 to +49.9 hPa) |
Resolution
|
0.01 hPa (-40 to +40 hPa)
0.1 hPa (-200 to +200 hPa) |
Absolute Pressure
|
|
---|---|
Measuring range
|
600 to +1150 hPa
|
Accuracy
|
±10 hPa
|
Resolution
|
1 hPa
|
Flue gas O₂ | |
---|---|
Measuring range
|
0 to +25 Vol.%
|
Accuracy
|
±0.8% of fsv (0 to +25 Vol.%)
|
Resolution
|
0.01 Vol.% (0 to +25 Vol.%)
|
Reaction time t₉₀
|
20s (t95)
|
Flue gas CO (with H₂-compensation)
|
|
---|---|
Measuring range
|
0 to +10000 ppm
|
Accuracy
|
±5 % of mv (+200 to +2000 ppm)
±10 % of mv (+2001 to +10000 ppm) ±10 ppm (0 to +199 ppm) |
Resolution
|
1 ppm (0 to +10000 ppm)
|
Reaction time t₉₀
|
40 s
|
Flue gas COlow
|
|
---|---|
Measuring range
|
0 to 500 ppm
|
Accuracy
|
±5 % of mv (+40 to +500 ppm)
±2 ppm (0 to +39.9 ppm) |
Resolution
|
1 ppm (0 to +500 ppm)
|
Reaction time t₉₀
|
40 s
|
Flue gas NO
|
|
---|---|
Measuring range
|
0 to +4000 ppm
|
Accuracy
|
±5 % of mv (+100 to +1999 ppm)
±10 % of mv (+2000 to +4000 ppm) ±5 ppm (0 to +99 ppm) |
Resolution
|
1 ppm (0 to +4000 ppm)
|
Reaction time t₉₀
|
30 s
|
Flue gas Nolow
|
|
---|---|
Measuring range
|
0 to +300 ppm
|
Accuracy
|
±5 % of mv (+40 to +300 ppm)
±2 ppm (0 to +39.9 ppm) |
Resolution
|
±0.1 ppm (0 to +300 ppm)
|
Reaction time t₉₀
|
30 s
|
Flue gas NO₂
|
|
---|---|
Measuring range
|
0 to +500 ppm
|
Accuracy
|
±5 % of mv (+100 to +500 ppm)
±5 ppm (0 to +9.99 ppm) |
Resolution
|
0.1 ppm (0 to +500 ppm)
|
Reaction time t₉₀
|
40 s
|
Flue gas SO₂
|
|
---|---|
Measuring range
|
0 to +5000 ppm
|
Accuracy
|
±5 % of mv (+100 to +2000 ppm)
±10 % of mv (+2001 to +5000 ppm) ±5 ppm (0 to +99 ppm) |
Resolution
|
1 ppm (0 to +5000 ppm)
|
Reaction time t₉₀
|
30 s
|
Flue gas degree of effectiveness, Eta (calculated)
|
|
---|---|
Measuring range |
0 to +120 %
|
Resolution
|
0.1 % (0 to +120 %)
|
Flue gas loss (calculated)
|
|
---|---|
Measuring range
|
0 to +99.9 %
|
Resolution
|
0.1 % (0 to +99.9 %)
|
Flue gas dewpoint (calculated)
|
|
---|---|
Measuring range
|
0 to +99.9 °Ctd
|
Resolution
|
0.1 °Ctd (0 to +99.9 °Ctd)
|
Flue gas CO₂ calculation (calculated from O₂)
|
|
---|---|
Measuring range
|
0 to CO₂ max
|
Accuracy
|
calculated from O₂ ±0.2 Vol.%
|
Resolution
|
0.01 Vol.%
|
Flue gas H₂S
|
|
---|---|
Measuring range
|
0 to +300 ppm
|
Accuracy
|
±5 % of mv (+40 to +300 ppm)
±2 ppm (0 to +39.9 ppm) |
Resolution
|
0.1 ppm (0 to +300 ppm)
|
Reaction time t₉₀
|
35 s
|
Flue gas CO₂ – NDIR
|
|
---|---|
Measuring range
|
0 to +50 Vol.%
|
Accuracy
|
±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%)
±0.5 Vol.% + 1.5 % of mv (25 to 50 Vol.%) |
Resolution
|
0.01 Vol.% (0 to 25 Vol.%)
0.1 Vol.% (> 25 Vol.%) |
Reaction time t₉₀
|
10 s
|
Velocity / Volume flow
|
|
---|---|
Measuring range
|
0 to +40 m/s
|
Resolution
|
0.1 m/s (0 to +40 m/s)
|
Methane (CH₄)
|
|
---|---|
Measuring range
|
100 to 40000 ppm
|
Accuracy
|
< 400 ppm (100 to 4000 ppm)
< 10 % of mv (> 4000 ppm) |
Resolution
|
10 ppm
|
Min. O₂ requirement in flue gas
|
2 % + (2 x mV methane)
|
Reaction time t₉₀
|
< 40 s
|
Response factor
|
1
|
Propane (C₃H₈)
|
|
---|---|
Measuring range
|
100 to 21000 ppm
|
Accuracy
|
< 400 ppm (100 to 4000 ppm)
< 10 % of mv (> 4000 ppm) |
Resolution
|
10 ppm
|
Min. O₂ requirement in flue gas
|
2 % + (5 x mV propane)
|
Reaction time t₉₀
|
< 40 s
|
Response factor
|
1.5
|
Butane (C₄H₁₀)
|
|
---|---|
Measuring range
|
100 to 18000 ppm
|
Accuracy
|
< 400 ppm (100 to 4000 ppm)
< 10 % of mv (> 4000 ppm) |
Resolution
|
10 ppm
|
Min. O₂ requirement in flue gas
|
2 % + (6.5 x mV butane)
|
Reaction time t₉₀
|
< 40 s
|
Response factor
|
2
|
General technical data |
|
---|---|
Housing
|
ABS
|
Protection class
|
IP40
|
Warranty
|
Measuring instrument 2 years (excepting wearing parts e.g. gas sensors);
CO, NO2, SO₂, H₂S, CxHy, NOlow sensor, NO, COlow: 12 months;
CO₂-IR sensors: 24 months; Sensor O₂: 18 months;
rechargeable battery: 12 months;
|
Battery type
|
lithium batteries
|
Battery life
|
5 h
|
Power supply
|
AC mains unit 100V to 240V (50 to 60 Hz)
|
DC electric tension input
|
11V to 40V
|
Pump flow
|
1 l/min. with through-flow monitoring
|
Hose length
|
16.2 m (corresponds to 5 probe hose extensions)
|
Max. pos. press./flue gas
|
50 mbar
|
Max. neg. press./flue gas
|
-300 mbar
|
Max. dust load
|
20 g/m³ dust in flue gas
|
Dewpoint calculation
|
0 °Ctd; 99 °Ctd
|
Max. humidity load
|
70 °C dewpoint temperature
|
Trigger input
|
Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA
|
Maximum
|
250,000 readings
|
Accessories
Probes
Kits
Certificates
Navigation
Information
Contact us