0632_3340_02
Testo 340_GB_Page_1
testo-340-Industrial-Flue-Gas-Analyser-details-probes-6_pdpz
testo-340-Industrial-Flue-Gas-Analyser-details-wireless-5_pdpz
testo-340-Industrial-Flue-Gas-Analyser-details-4_pdpz
testo-340-Industrial-Flue-Gas-Analyser-pipe-industry-2_pdpz
Previous
Next

testo 340 – Flue gas analyzer for use in industry

Cat. Number: 0632 3340

testo 340 flue gas analyzer incl. rechargeable battery, instruction manual and carry strap, equipped with O2 sensor and built-in flow/differential pressure measurement

  • Category: Flue gas analyzers for industry and power generation, Flue gases
  • Branch: Energy efficiency, Flue gas analysis
  • Manufacturer: TESTO AG
Call us
Make an inquiry

Video

Files

Loading...

Brochure-Testo 340-2018

Description
Technical data
Description

Rising fuel costs for thermal systems highlight more and more the need for efficiency monitoring using emission measurements. A practical, easy-to-use emission analyzer for a variety of applications is therefore ideal. testo 340 is equipped with an O2 sensor as standard. 3 additional gas sensors can be individually configured at any time so your analyzer is optimally adpated to your measurement job. Compact design combined with reliable engineering makes testo 340 the ideal analyzer for commissioning, service and maintenance work as well as measurements for monitoring purposes. • Industrial burners • Stationary industrial engines • Gas turbines • Thermal processes

  • precalibrated „plug & play“ sensors
  • 3 sensors freely selectable (O2 standard, a second sensor must be fitted) CO, COlow, NO, NOlow, NO2 und SO2
  • pressure-/ flow-measurement standard in every testo 340
  • measurement range extension for Single dilution slot or optional for all sensors
  • automatic flow-controlled gas pump
  • modular gas sampling probes
  • internal data logging
  • option: Data transfer and real-time-analyzer-control via Bluetooth® module and software easyEmission
  • 18 standard fuels and additional 10 user-defined fuels – Fuel data is calculated using software easyEmission
testo 340 must be equipped with a second gas sensor otherwise the analyzer cannot function. Max. 3 additional sensors can be fitted.
 
Application
 
Software
Technical data
Differential Pressure
Measuring range                                                  
-200 to 200 hPa                                           
Accuracy
±0.5 hPa (-49.9 to 49.9 hPa)
±1.5 % of mv (Remaining Range)
Resolution
0.1 hPa
 
Absolute Pressure
Measuring range                                                 
+240 to +460 InH₂O / +600 to +1150 hPa    
Accuracy
±4 InH₂O / ±10 hPa
Resolution
0 InH₂O / 1 hPa
 
Flue gas O₂

 Measuring range                                                

0 to 25 Vol.%                                                 
Accuracy
±0.2 Vol.%
Resolution
0.01 Vol.%
Reaction time t₉₀
< 20 sec
 
Flue gas CO (with H₂-compensation)
Measuring range                                                 
0 to 10000 ppm                                              
Accuracy
±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 10000 ppm)
Resolution
1 ppm
Reaction time t₉₀
< 40 sec
 
Flue gas COlow
Measuring range                                              
0 to 500 ppm
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of remaining measurement value
(Remaining Range) data corresponds to
20°C ambient temperature. Additional temperature
coefficient 0.25% of reading/K.
Resolution
0.1 ppm
Reaction time t₉₀
< 40 sec
 
Flue Gas NO
Measuring range                              
0 to 4000 ppm
Accuracy
±5 ppm (0 to 99 ppm)
±5 % of remaining measurement value (100 to 1999 ppm)
±10 % of remaining measurement value (2000 to 4000 ppm)
Resolution
1 ppm
Reaction time t₉₀
< 30 sec
 
Flue Gas No low
Measuring range                              
0 to 300 ppm                                                                          
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of remaining measurement value (Remaining Range)
Resolution
0.1 ppm
Reaction time t₉₀
< 30 sec
 
Flue Gas NO₂
Measuring range                                
0 to 500 ppm
Accuracy
±10 ppm (0 to 199 ppm)
±5 % of remaining measurement value (Remaining Range)
Resolution
0.1 ppm
Reaction time t₉₀
< 40 sec
To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
 
Flue Gas SO₂
Measuring range                               
0 to 5000 ppm
Accuracy
±10 ppm (0 to 99 ppm)
±10 % of remaining measurement value (Remaining Range)
Resolution
1 ppm
Reaction time t₉₀
< 40 sec
To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
 
Flue Gas Draft
Measuring range                     
-16 to +16 InH₂O / -40 to +40 hPa
Accuracy
±0.01 InH₂O (-1.20 to +1.20 InH₂O) / ±0.03 hPa (-2.99 to +2.99 hPa)
±1.5 % of remaining measurement value (Remaining Range)
Resolution
0.00 InH₂O / 0.01 hPa
 
Temperature
Measuring range                     
-40.0° to 2192.0 °F / -40 to +1200 °C                                                 
Accuracy
±0.9 °F (32.0° to 210.2 °F) / ±0.5 °C (0 to +99 °C)
±0.5 % of remaining measurement value (Remaining Range)
Resolution
0.1 °F / 0.1 °C
 
Efficiency (calculated)
Measuring range                    
0 to 120 %                                                                                          
Resolution
0.1 %
 
Flue Gas loss (calculated)
Measuring range                    
0 to 99.9 %                                                                                        
Resolution
0.1 %
 
Flue Gas dewpoint (calculated)
Measuring range                    
0.0° to 99.9 °Ctd                                                                              
Resolution
0.1 °Ctd
 
Flue Gas CO₂ calculation (calculated from O₂)
Measuring range                   
0 to CO₂ max                                                                                   
Accuracy
±0.2 Vol.%
Resolution
0.1 Vol.%
Reaction time t₉₀
< 40 sec
 
General technical data
Housing
TPE PC
Protection class
IP40
Warranty
Measuring instrument 2 years (excepting wearing parts e.g. gas sensors, etc.);
rechargeable battery: 12 months; CO sensor: 12 months; Sensor NOlow: 12 months;
Sensor NO2: 12 months; Sensor SO₂: 12 months; Sensor O₂: 18 months;
NO sensor 12 months; COlow sensor 12 months
Display size
160 x 240 pixels
Display function
Graphic display
Power supply
Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A
User defined fuels
10 user-defined fuels incl. test gas as fuel
Pump flow
0.6 l/min (regulated)
Hose length
max. 7.8 m (corresponds to two probe hose extensions)
Max. pos. press./flue gas
50 mbar
Max. neg. press./flue gas
-200 mbar
Maximum
100 folders
Storage per folder
Max. 10 sites
Storage per site
Max. 200 logs
Miscellaneous
The max. number of logs is determined by the number of folders or sites

Accessories

Loading...

Transport case for probes

Кат. номер: 0516 7600

Suitable for all probeswith a total lenght >335 mm

CO replacement filter, 1 off

Кат. номер: 0554 4100

NO replacement filter, 1 off

Кат. номер: 0554 4150

Option: NOlow measurement module, 0 to 300 ppm

Кат. номер: 0393 1152

1 2 … 6

Probes

Loading...

Industrial probe set 1?800 °C

Кат. номер: 0600 7620

– unheated handle – unheated probe shaft up to 1800 °C flue gas temperature – unheated gas sampling hose incl. inline filter, length 4

Spare particle filter (10 off) for probe handle

Кат. номер: 0554 3385

Flue gas probe for industrial motors

Кат. номер: 0600 7560

335 mm immersion depth, with probe stop, built-in condensate trap and heat protection plate, Tmax 1000 °C, special hose for NO2/SO2 measurements, 2.2 m

Flue gas probe for industrial motors with probe shaft prefilter

Кат. номер: 0600 7561

335 mm immersion depth, with probe stop, built-in condensate trap and heat protection plate, Tmax 1000 °C, special hose for NO2/SO2 measurements, 2.2 m

Thermocouple for exhaust gas temperature measurement

Кат. номер: 0600 8894

(NiCr-Ni, length 400 mm, Tmax. +1000 °C), with 2.4 m connection cable and additional temperature protection

Spare particle filter (10 off)

Кат. номер: 0554 3371

For condensate trap in gas sampling hose
1 2 … 6

Kits

Loading...

Certificates

Loading...

ISO calibration certificate/flue gas

(calibration points 2.5% O2; 100 and 1000 ppm CO; 800 ppm NO; 80 ppm NO2; 1000 ppm SO2)

ISO calibration certificate velocity

(hot wire, vane anemometer, Pitot tube; calibration points 1; 2; 5; 10 m/s)

ISO calibration certificate/Velocity

(hot wire, vane anemometer, Pitot tube; calibration points 5; 10; 15; 20 m/s)
1 2
0632_3340_02
Testo 340_GB_Page_1
testo-340-Industrial-Flue-Gas-Analyser-details-probes-6_pdpz
testo-340-Industrial-Flue-Gas-Analyser-details-wireless-5_pdpz
testo-340-Industrial-Flue-Gas-Analyser-details-4_pdpz
testo-340-Industrial-Flue-Gas-Analyser-pipe-industry-2_pdpz
Previous
Next

Navigation

  • Home
  • About us
  • Services
  • RES
  • Contact
Menu
  • Home
  • About us
  • Services
  • RES
  • Contact

Information

  • Terms & Conditions
  • Privacy
  • Cookies
Menu
  • Terms & Conditions
  • Privacy
  • Cookies

Contact us

  • Mon. - Fri. from 08:30 to 17:30
  • 1700 Sofia, Darvenitsa residential area, Prof. Georgi Bradistilov St. No. 4, floor 2, office 2.1
  • +359 2 953 07 96
  • +359 899 904 493
  • office@global-test.eu

Website development by Royal Technology LTD

Вие изпратихте успешно вашето запитване, ще се свържем с вас в най-кратки срокове, благодарим ви за доверието.